{"id":43,"date":"2026-09-17T05:16:32","date_gmt":"2026-09-17T05:16:32","guid":{"rendered":"https:\/\/www.tekson.in\/blog\/?p=43"},"modified":"2026-09-17T05:16:32","modified_gmt":"2026-09-17T05:16:32","slug":"indias-rooftop-solar-boom-2026-solar-dc-cables-earthing-electrical-bos-guide-tekson","status":"publish","type":"post","link":"https:\/\/www.tekson.in\/blog\/indias-rooftop-solar-boom-2026-solar-dc-cables-earthing-electrical-bos-guide-tekson\/","title":{"rendered":"India\u2019s Rooftop Solar Boom 2026: Solar DC Cables, Earthing &#038; Electrical BOS Guide | Tekson"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">India\u2019s solar market is no longer growing only through large utility-scale projects. Rooftop systems on homes, commercial buildings, factories, warehouses and institutions are becoming an increasingly important part of the country\u2019s energy infrastructure.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">According to the Ministry of New and Renewable Energy, India\u2019s cumulative solar capacity reached <strong>168.04 GW by 31 August 2026<\/strong>, of which <strong>32.59 GW came from grid-connected rooftop solar installations<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As rooftop solar deployment increases, attention naturally goes to modules and inverters. But the long-term reliability of a solar installation also depends heavily on something less visible: the <strong>electrical balance of system<\/strong>, or electrical BOS.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Solar DC cables, armoured cables, earthing conductors, flexible routing products, elbows, tees, saddles, distribution equipment and properly coordinated protection all contribute to how safely and practically a solar installation operates over time.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For solar EPC contractors, installers, electrical consultants and procurement teams, choosing these supporting components correctly is becoming increasingly important.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What Is the Electrical Balance of System in a Solar Project?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The balance of system includes the equipment and materials required to connect, route, protect, distribute and support the electrical side of a solar installation beyond the photovoltaic module itself.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Depending on the size and design of the project, this can include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Solar DC wires<\/li>\n\n\n\n<li>AC power cables<\/li>\n\n\n\n<li>Aluminium armoured cables<\/li>\n\n\n\n<li>Copper or aluminium earthing cables<\/li>\n\n\n\n<li>Flexible pipe<\/li>\n\n\n\n<li>PVC elbows and tees<\/li>\n\n\n\n<li>GI or MS saddles<\/li>\n\n\n\n<li>Cable-routing accessories<\/li>\n\n\n\n<li>Distribution equipment<\/li>\n\n\n\n<li>Protective devices<\/li>\n\n\n\n<li>Junction and termination accessories<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These components may look secondary compared with solar modules, but they are part of the physical electrical path that carries energy from generation to utilisation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Poor component selection can make installation, maintenance and future expansion unnecessarily difficult.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1. Solar DC Cables: The Connection Between Modules and the Electrical System<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Solar DC wiring operates on the generation side of the photovoltaic system and forms a critical connection between modules, string arrangements and downstream equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When selecting a <strong>Solar DC cable<\/strong>, engineers and installers should consider the actual project environment rather than looking only at conductor size.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Important factors include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>System voltage<\/li>\n\n\n\n<li>Operating current<\/li>\n\n\n\n<li>Route length<\/li>\n\n\n\n<li>Voltage drop<\/li>\n\n\n\n<li>Ambient temperature<\/li>\n\n\n\n<li>Cable grouping<\/li>\n\n\n\n<li>Outdoor exposure<\/li>\n\n\n\n<li>Installation method<\/li>\n\n\n\n<li>Bending radius<\/li>\n\n\n\n<li>Termination compatibility<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Outdoor solar installations expose cables to conditions that may differ significantly from conventional indoor wiring. The specified cable construction therefore needs to match the environmental and electrical requirements of the installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cable sizing should also account for voltage drop over the complete cable route. Longer rooftop or ground-mounted runs may require a different conductor size even when the thermal current requirement appears satisfactory.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For a broader explanation of electrical cable selection, read:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.tekson.in\/blog\/choose-industrial-power-cable\/\"><strong>How to Choose the Right Cable for Industrial Applications<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2. Cable Routing Is Becoming More Important as Rooftop Systems Grow<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A rooftop solar installation can contain numerous cable runs travelling between modules, inverter locations, service areas and electrical rooms.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">These routes should not become an afterthought.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Good cable routing supports:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Easier inspection<\/li>\n\n\n\n<li>Reduced mechanical stress<\/li>\n\n\n\n<li>Better maintenance access<\/li>\n\n\n\n<li>Clear separation of circuits where required<\/li>\n\n\n\n<li>More organised installation<\/li>\n\n\n\n<li>Protection at transitions and exposed routes<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Flexible pipe can be useful where the route requires movement around structural elements or equipment, provided the selected product is appropriate for the installation environment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tekson\u2019s solar-industry product range identified for such applications includes <strong>Black Flexible Pipe, PVC Elbow and PVC Tee<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The important design principle is not simply to enclose every cable. The routing system needs to suit the mechanical, environmental and service requirements of the particular project.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For additional guidance, read:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.tekson.in\/blog\/pvc-vs-metal-conduit-fittings\/\"><strong>PVC vs Metal Conduit Fittings: Which Should You Choose?<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3. Aluminium Armoured Cables for Demanding Power Routes<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Not every cable run in a solar project is a module-level DC connection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Larger projects can also require power distribution between inverters, panels, transformers, auxiliary systems or other electrical equipment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Where mechanical protection is required, <strong>armoured power cables<\/strong> may form part of the project design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tekson\u2019s range includes <strong>LT Aluminium Power Cables<\/strong>, including armoured constructions across multiple conductor sizes.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The correct cable for a project should be determined by factors such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Current demand<\/li>\n\n\n\n<li>System voltage<\/li>\n\n\n\n<li>Fault conditions<\/li>\n\n\n\n<li>Installation environment<\/li>\n\n\n\n<li>Route length<\/li>\n\n\n\n<li>Voltage drop<\/li>\n\n\n\n<li>Mechanical exposure<\/li>\n\n\n\n<li>Cable support method<\/li>\n\n\n\n<li>Project specifications<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Armour should never be treated as a substitute for proper engineering. The full cable system\u2014including conductor, insulation, mechanical protection, termination and protective device\u2014needs to work together.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">4. Earthing Is a System, Not Just an Earth Wire<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Earthing is one of the most important electrical safety considerations in any solar installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A solar system can contain multiple metallic structures and electrical components, including mounting systems, enclosures, cable armour, inverter equipment and distribution assemblies.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The earthing design therefore needs to be considered as a complete system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tekson\u2019s client-priority solar range includes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Copper Earthing Cables<\/strong><\/li>\n\n\n\n<li><strong>Aluminium Earthing Cables<\/strong><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Selection should follow the project design, applicable standards, environmental conditions and required conductor sizing.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Important considerations include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Continuity of the protective path<\/li>\n\n\n\n<li>Suitable conductor sizing<\/li>\n\n\n\n<li>Reliable terminations<\/li>\n\n\n\n<li>Mechanical protection<\/li>\n\n\n\n<li>Corrosion compatibility<\/li>\n\n\n\n<li>Proper identification<\/li>\n\n\n\n<li>Inspection accessibility<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">A technically correct earthing installation depends as much on workmanship and connection quality as on the conductor itself.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">5. GI and MS Saddles: Small Components With a Practical Job<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cable-support hardware is easy to overlook during procurement.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">However, long electrical routes need suitable physical support.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>GI and MS saddles<\/strong> can form part of a properly planned cable or pipe-support system where appropriate for the installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Support spacing, material selection and fixing methods should be based on the route, load, environment and project specification.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The goal is simple: cables and routing products should remain organised and mechanically supported rather than relying on improvised fixing methods.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For EPC contractors, these apparently small accessories become particularly important when installations need to remain neat and maintainable across hundreds of metres of routing.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">6. Distribution and Protection Must Be Designed Together<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As solar power enters the building or facility electrical system, distribution and circuit protection become another important part of the design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A distribution board should not simply be viewed as an enclosure containing breakers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Designers need to consider:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Incoming and outgoing circuits<\/li>\n\n\n\n<li>Available fault current<\/li>\n\n\n\n<li>Cable capacity<\/li>\n\n\n\n<li>Breaking capacity of protective devices<\/li>\n\n\n\n<li>Circuit identification<\/li>\n\n\n\n<li>Wiring space<\/li>\n\n\n\n<li>Heat management<\/li>\n\n\n\n<li>Future expansion<\/li>\n\n\n\n<li>Maintenance access<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">For more information, read:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.tekson.in\/blog\/distribution-board-safety-checklist\/\"><strong>Distribution Board Safety: A Practical Planning Checklist<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The relationship between <strong>MCBs and MCCBs<\/strong> is also important in electrical distribution. These devices serve different current, fault-level and application requirements, so selection needs to be based on system design rather than appearance or nominal rating alone.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.tekson.in\/blog\/mcb-vs-mccb-circuit-protection\/\"><strong>MCB vs MCCB: Understanding the Right Circuit Protection<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For solar installations specifically, protective devices must also be suitable for the circuit and duty for which they are being used. A device intended for one application should never be assumed suitable for another without checking its technical specification.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">7. Why Solar EPC Procurement Is Moving Beyond the Module and Inverter<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">As the Indian rooftop solar sector grows, EPC contractors increasingly need to think about the entire installation ecosystem.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A project can lose time not because a solar panel is unavailable, but because a specific cable, fitting, support accessory or distribution component is missing when installation reaches that stage.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This makes material planning increasingly important.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For contractors and procurement teams, it helps to prepare a detailed electrical BOS schedule covering:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Generation-Side Wiring<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Solar DC cables and associated routing.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Power Distribution<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Appropriately selected power and armoured cables.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Earthing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Copper or aluminium conductors as specified by the project.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Cable Protection and Routing<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Flexible pipe, elbows, tees and related fittings.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mechanical Support<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Suitable GI\/MS saddles and fixing arrangements.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Distribution and Protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Boards, switchgear and coordinated protection according to the electrical design.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A complete procurement schedule reduces last-minute substitution and helps maintain consistency across the installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">8. Installation Quality Matters as Much as Product Selection<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Even correctly specified electrical products can perform poorly when installation workmanship is inadequate.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Solar EPC teams should pay close attention to details such as:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cable bending radius<\/li>\n\n\n\n<li>Suitable termination tools<\/li>\n\n\n\n<li>Correct lug and connector selection<\/li>\n\n\n\n<li>Cable support<\/li>\n\n\n\n<li>Entry protection<\/li>\n\n\n\n<li>Proper tightening and torque<\/li>\n\n\n\n<li>Circuit identification<\/li>\n\n\n\n<li>Separation and routing<\/li>\n\n\n\n<li>Weather protection<\/li>\n\n\n\n<li>Inspection before commissioning<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Cable routes should also allow future maintenance without requiring unnecessary dismantling of surrounding systems.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A professional installation should be understandable to the next electrician who has to inspect or maintain it.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">9. Plan for Maintenance Before the Installation Is Built<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Rooftop solar assets are expected to operate for many years.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Electrical design should therefore consider not only commissioning but also future inspection and maintenance.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Installers should ask:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Can cables be visually inspected?<\/li>\n\n\n\n<li>Are important joints accessible?<\/li>\n\n\n\n<li>Can damaged routing components be replaced?<\/li>\n\n\n\n<li>Are circuits clearly identified?<\/li>\n\n\n\n<li>Is sufficient space available around distribution equipment?<\/li>\n\n\n\n<li>Can the installation be expanded without overcrowding existing equipment?<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">These questions often determine whether a system remains straightforward to maintain years after installation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Solar Growth Makes Electrical BOS More Important, Not Less<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The growth of rooftop solar is changing the electrical installation landscape in India.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Modules and inverters may remain the most visible equipment, but dependable projects rely on the complete electrical path around them.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Solar DC wires, armoured cables, earthing cables, flexible pipe, PVC elbows, PVC tees, GI\/MS saddles, distribution equipment and correctly coordinated protection<\/strong> all contribute to an organised and maintainable installation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For EPC contractors and electrical professionals, the most reliable approach is to treat these components as an engineered system rather than a list of accessories purchased at the end of the project.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tekson supplies electrical products across cable, switchgear, distribution and installation categories for industrial, commercial and project requirements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Its cable range includes automation cables, shielded cables, Teflon wire, fiber glass wire, control cables and industrial power cables alongside other electrical solutions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.tekson.in\/products\/cables\/\"><strong>Explore Tekson Cables &amp; Wires<\/strong><\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Website:<\/strong> <a href=\"https:\/\/www.tekson.in\/\">www.tekson.in<\/a><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">What electrical components are required for a rooftop solar installation?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Requirements vary by system design, but commonly considered electrical BOS components include Solar DC cables, AC power cables, earthing conductors, cable-routing products, support hardware, distribution equipment and protective devices.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why is Solar DC cable selection important?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The cable must suit the system voltage, current, route length, installation method and environmental conditions. Voltage drop, temperature, grouping and termination compatibility should also be considered.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Are armoured cables required in every solar installation?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">No. The requirement depends on the route, mechanical exposure, installation method and project specification. Cable construction should be selected by the project designer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can copper and aluminium both be used for earthing?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Both materials are used in electrical systems, but conductor selection and sizing depend on the project design, applicable standards, connection methods and environmental conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">What is the purpose of flexible pipe in solar installations?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Where appropriate, flexible pipe can provide an organised protected route around changes in direction, structural features or equipment. The selected product must suit the actual environment and installation conditions.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Why are GI\/MS saddles important?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">They provide mechanical support for suitable cable-routing systems. Correct support helps keep routes organised and reduces unnecessary mechanical stress.<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\">About Tekson<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tekson Cable House supplies electrical products for industrial, commercial and electrical-distribution requirements, including cables, switchgear, distribution boxes and installation accessories.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Explore the complete range at <a href=\"https:\/\/www.tekson.in\/\"><strong>www.tekson.in<\/strong><\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>India\u2019s solar market is no longer growing only through large utility-scale projects. Rooftop systems on homes, commercial buildings, factories, warehouses and institutions are becoming an increasingly important part of the country\u2019s energy infrastructure. According to the Ministry of New and Renewable Energy, India\u2019s cumulative solar capacity reached 168.04 GW by 31 August 2026, of which [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":44,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[37,46,47],"tags":[61,60,73,62],"class_list":["post-43","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-automation-cables","category-mcb-boxes","category-mccb-boxes","tag-fan-down-rod","tag-fan-parts","tag-tt-tape","tag-tekson-tape"],"_links":{"self":[{"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/posts\/43","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/comments?post=43"}],"version-history":[{"count":1,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/posts\/43\/revisions"}],"predecessor-version":[{"id":45,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/posts\/43\/revisions\/45"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/media\/44"}],"wp:attachment":[{"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/media?parent=43"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/categories?post=43"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tekson.in\/blog\/wp-json\/wp\/v2\/tags?post=43"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}